Description of SolarEdge SE100K
Powered by unique pre-commissioning process for rapid system installation • Pre-commissioning feature for automated system validation and wiring during site installation and prior to grid connection • Easy two-person installation with lightweight, modular design (each inverter consists of two or three Synergy Units and one Synergy Manager) • Independent operation of each Synergy Unit enables higher uptime and easy serviceability • Advanced, built-in safety features include: • Thermal sensors that detect faulty wiring • SafeDC™ - designed to automatically reduce high DC voltage to safe levels upon grid/inverter shutdown, with optional Rapid Shutdown • Arc fault protection • Optional integrated DC safety switch eliminates the need for external DC isolators • Built-in PID mitigation for maximized performance • Monitored* and field-replaceable surge protection devices to better withstand power surges • Built-in module-level monitoring with Ethernet or cellular communication for full system visibility • Inverter power rating is set during commissioning, resulting in fewer part numbers for simplified inventory and operations • *Applicable only for DC and AC SPDs
Technical data of SolarEdge SE100K
| Series Name | SE |
|---|---|
| Series AC Power Range (kW) | 50-100 |
| Model Name | SE100K |
| Maximum DC Power (kW) | 175 |
| Max. DC Voltage (V) | 1000 |
| Max. DC Current (A) | 3 x 48.25 |
| Solar Panel Connectors | MC4 pairs |
| Maximum AC Power (kW) | 100 |
| Output AC Voltage Range (V) | 304-437 / 176-253; 320-460 / 184-264.5 |
| Nominal AC Voltage (V) | 380/220, 400/230 |
| Maximum AC Current (A) | 145 |
| Frequency (Hz) | 50/60 |
| Distortion (THD) ( < X%) | 3 |
| Maximum Efficiency (%) | 98.3 |
| Euro Efficiency (%) | 98 |
| AC Output Connection | 3W + PE, 4W + PE |
| Night Power Consumption ( < W) | 12 |
| Noise Level (dB(A)) | 67 |
| Operating Temperature Range (°C) | -40~+60 |
| Protection Class | IP65 |
| Cooling | Active cooling |
| Interface | 2 x RS485, Ethernet; Wi-Fi (optional), Cellular (optional) |
| Protection Features | • Reverse-Polarity Protection • Ground-Fault Isolation Detection (167 kΩ sensitivity per Synergy Unit) • Arc Fault Protection (Built-in, User Configurable) • Rapid Shutdown (RSD) (optional) • RS485 Surge Protection (Type II, field replaceable, integrated) • DC Surge Protection (Type II, field replaceable, integrated) • AC Surge Protection (Type II, field replaceable, optional) |
Dimensions and weight of SolarEdge SE100K
| Height (mm) | 558 |
|---|---|
| Width (mm) | 328 |
| Depth (mm) | 273 |
| Weight (kg) | 32 |
From €3,275.00