| Inverter Type | Hybrid |
| Number of phases | 3 |
| Inverter Type | Hybrid |
| Number of phases | 3 |
| Series Name | blueplanet gridsave TL3-S |
| Model Name | blueplanet gridsave 92.0 TL3-S M |
| Max. DC Voltage (V) | 1315 |
| Min. DC Voltage to Start Feed In (V) | 668 |
| Nominal DC current (A) | 145 |
| Solar Panel Connectors | M10 ring cable lug |
| Output AC Voltage Range (V) | 300-580 |
| Nominal AC Voltage (V) | 400 |
| Maximum AC Current (A) | 132.3 |
| Nominal AC Current (A) | 132.3 |
| Frequency Range (Hz) | 45-65 |
| Frequency (Hz) | 50/60 |
| Power Factor | 0.3 leading...0.3 lagging |
| Distortion (THD) ( < X%) | 3 |
| AC Output Connection | Cable lug |
| Noise Level (dB(A)) | 60 |
| Operating Temperature Range (°C) | -20~+60 |
| Transformer | Transformerless |
| Protection Class | IP66 |
| Humidity (%) | 100 |
| Cooling | Active cooling |
| Max Altitude (m) | 3000 |
| Interface | 2 x Ethernet, RS485, USB, SD slot, INV OFF, Error-Relais; TCP/IP, Modbus TCP based on Sunspec, KACO protocol |
| Display | LEDs |
| Protection Features | • Overvoltage conductor / varistor to protect the power semiconductors from high-energy transients on the grid and generator sides. • Device temperature monitoring system • EMC filter to protect the product from high-frequency grid interference • Grid-side varistors grounded to earth to protect the product against burst and surge pulses • Anti-islanding detection according to the current standards |
| Height (mm) | 719 |
| Width (mm) | 699 |
| Depth (mm) | 450 |
| Weight (kg) | 78 |